Top

ULTIMAFLOOR® SATIN : Two-component clear varnish for heavy traffic

EAN :
  • Water-based Water-based
  • Indoor outdoor Indoor outdoor

Description

ULTIMAFLOOR® is a high-performance water-based sealant with excellent filling power and optimum mechanical and chemical resistance.

Ultimafloor protects and enhances the wood grain, and is non-slip, lightfast and NON-slip to guarantee long-lasting protection.


This colourless, matt, odourless sealant will not yellow over time.

Properties

Enhances and protects staircases, parquet and floors
floors.
▪ Excellent filling power.
▪ Insensitive to light, does not yellow over time.
▪ Optimum mechanical and chemical resistance, including.
▪ To ammoniated products.
▪ Non-slip.

Destination

▪ Can be applied to all types of wood
▪ Heavy traffic: corridors, staircases, dining rooms.
▪ Heavy traffic: offices, shops, classrooms, restaurants,
museums, building lobbies, hotels...
▪ Work surface

Recommendations before application

- To avoid deep scratches caused by sanding, carry out a test sanding using a parquet sander fitted with a
40 or 50 grit.
- Depending on the visual result obtained, continue gradually with a finer grit up to 80 or 100 or
start with a coarser grit (< 40 grit) for a dirty floor that has not been levelled.
- Use an edger for the edges and a scraper or chisel for the corners.
- If necessary, fill cracks < 2 mm with LIANFLOOR®* and sand again with 80 or 100 grit, depending on the last grit used.
last grain used.
- Finish with finishing sanding to grit nos. 120 to 150 depending on the species and thickness of the wear layer.
TOUGH ADVICE :
- Follow the grading scale above. It is recommended that only one grit is skipped at a time.
- Adapt the sanding pressure and speed according to the grit used, the nature of the wood (softer or softer) and the thickness of the wear layer.
the thickness of the wear layer. Good preparation is essential for the final appearance of the finish.
- Always remove dust thoroughly with a hoover between each sanding, not forgetting the dust traps
(skirting boards, radiators, pipes, window sills, etc.).
- Previously oiled or waxed floors: first, dry stripping followed by degreasing before sanding (consult us).
- In all cases, comply with current standards/DTU.

Application

- Apply an even, full first coat of ULTIMAFLOOR®. Make 3 cross passes in one application
application, facing the light and starting on the side opposite the door so as to progress towards it.
towards the door.
- Start at the edges and work over the entire surface in 2 m x 2 m areas.
- Leave to dry for 4 hours, depending on ambient conditions.
- Sanding (grit size 150 to 180), then remove all dust.
- Apply the 2nd coat of ULTIMAFLOOR®. Do not allow more than 12 hours between the 2 coats.
coats.
Application temperature +10°C to +25°C
Finish Satin
Coverage per coat 10 to 12 m²/l
Dangerous. Observe safety precautions. UFL hardener: Dangerous. Observe the precautions for use. *Information on the level of emissions of volatile substances into indoor air, presenting a risk of toxicity by inhalation, on a class scale from A+ (very low emissions) to C (high emissions).